Load capacity of steel-aluminium brackets under static and cyclic laboratory tests

Authors

DOI:

https://doi.org/10.24425/ace.2021.137156

Abstract

The aim of the research is the laboratory investigation of steel-aluminium brackets employed to fasten lightweight curtain walls to building facilities. Static pressure, suction forces, and cyclic loads parallel to end plates (horizontal - to simulate wind influence) were applied in the study. The steel-aluminium brackets were tested on a reinforced concrete substrate made of C30/37 concrete class to simulate the real working conditions. Laboratory tests were performed to failure of the brackets or damage of anchoring fastened to the concrete elements. Additionally, the tensile capacity of stainless steel bolt connections screwed in aluminium profile was determined. The uniaxial tensile tests were performed for three length variants of the anchorage: 28 mm, 14 mm, and 7 mm of the stainless steel bars screw-in in threading aluminium profiles. In the course of cyclic tests, a hinge formed in the location of bolt connections made the change of the working character of steel-aluminium brackets. The cyclic tests also showed the danger of the strap aluminium profile displacement due to improper connection with the main aluminium profile. The paper is intended to provide scientists, civil engineers, and designers with an experimental assessment of mechanical properties of steel-aluminium brackets under static and cyclic loads.

References

[1] G. Akhmadullina and G. Shmelev, “Numerical modeling and optimization of geometric parameters of a composite bracket,” IOP Conf. Ser. Mater. Sci. Eng., vol. 890, pp. 012051, 2020. https://doi.org/10.1088/1757-899X/890/1/012051

[2] Aluprof, Projekt Specific & Bespoke Solutions, (n.d.). https://aluprof.eu/files/downloads/katalog%20_rozwiazan_indywidualnych(kri)pl_en.pdf (accessed July 29, 2020)

[3] A. Ambroziak, “Mechanical Properties of Aluminium Bracket Strengthening,” Arch. Civ. Eng. 65 (2019) 203–216. https://doi.org/10.2478/ace-2019-0055

[4] T. Z. Błaszczyński, “Ekologiczne wieżowce,” Builder, vol. 262, no. 5, pp. 86-89, 2019. http://dx.doi.org/10.5604/01.3001.0013.3610

[5] M. Brzezicki, “Glass protected timber façades - new sustainable façade typology,” Tech. Trans., vol. 5, pp. 5-22, 2019. https://doi.org/10.4467/2353737XCT.19.050.10574

[6] L. Casagrande, A. Bonati, F. Auricchio and A. Occhiuzzi, Dissipating effect of glazed curtain wall stick system installed on high-rise mega-braced frame-core buildings under nonlinear seismic excitation, in: COMPDYN 2017 - Proc. 6th Int. Conf. Comput. Methods Struct. Dyn. Earthq. Eng., 2017, pp. 3711-3727. https://doi.org/10.7712/120117.5677.17166

[7] CEN (European Committee for Standardization), EN 755-2: Aluminium and aluminium alloys. Extruded rod/bar, tube and profiles - Part 2: Mechanical properties, (2016).

[8] CEN (European Committee for Standardization), “EN 206:2013+A1:2016 Concrete - Specification, performance, production and conformity,” 2016, pp. 1-74.

[9] M. Cwyl, “Podstawowe wymagania normowe współczesnych ścian metalowo-szklanych,” Inżynieria i Bud., vol. 69, no. 6, pp. 305-307, 2013.

[10] DIBt (Deutsches Institut für Bautechnik), “ETA-05/0069 fischer Bolt Anchor FAZ II. Torque controlled expansion anchor of sizes M8, M10, M12, M16, M20 and M24 for use in concrete,” 2016, pp. 1-21.

[11] O. Fedorov and V. Lazina, Modern translucent enclosures in architecture, Archit. Eng. 4 (2019) 12-21. https://doi.org/10.23968/2500-0055-2019-4-4-12-21

[12] A. V. Galyamichev, V. A. Kirikova, G. E. Gerasimova and A. Sprince, “Bearing capacity of facade systems fixing to sandwich panels,” Mag. Civ. Eng., vol. 78, pp. 30-46, 2018. https://doi.org/10.18720/MCE.78.3

[13] M. Górka and A. Leśniak, Systemy fasad aluminiowo-szklanych i ich ocena wielokryterialna, Zesz. Nauk. Politech. Częstochowskiej. Bud. 174 (2018) 102-107. https://doi.org/10.17512/znb.2018.1.16

[14] M. Jaworska-Michałowska, “Szklane fasady w budynkach kształtowanych przez klimat - wybrane zagadnienia,” Przegląd Bud., vol. 7-8, pp. 43-46, 2010. https://www.przegladbudowlany.pl/2010/07-8/2010-7-8-PB-43-46_Jaworska.pdf

[15] K. Kazmierczak, “Review of curtain walls, focusing on design problems and solutions,” in: Build. Enclos. Sci. Technol., Portland, USA, 2010: pp. 1-20. https://cdn.ymaws.com/www.nibs.org/resource/resmgr/best/best2_008_ee4-1.pdf

[16] M. Kołaczkowski and A. Byrdy, FEM Analysis and Experimental Research into Carrier Brackets in Ventilated Facades, Period. Polytech. Civ. Eng. (2020) 1-9. https://doi.org/10.3311/ppci.13822

[17] A. Leśniak and M. Górka, Structural Analysis of Factors Influencing the Costs of Facade System Implementation, Appl. Sci. 10 (2020) 6021. https://doi.org/10.3390/app10176021

[18] A. Leśniak, D. Wieczorek and M. Górka, Costs of facade systems execution, Arch. Civ. Eng., vol. 66, no. 4, pp. 81-95, 2020. https://doi.org/10.24425/ace.2020.131776

[19] D. D. Mijovic, D. Milanovic and S. Jelena, “Curtain walls: history and a continuing challenge,” in: XVIII Int. Sci. Conf. "Construction Archit. VSU 2018, Sofia, Bulgaria, 2018, pp. 1-6.

[20] PKN (Polish Committee for Standardization), “PN-EN 13830 Curtain walling. Product standard,” 2020, pp. 1- 92.

[21] J. Č. Tovarović, N. Šekularac and J. Ivanović-Šekularac, “Problems Associated With Curtain Walls,” Struct. Eng. Int., vol. 27, pp. 413-417, 2017. https://doi.org/10.2749/101686617X14881937385322

Downloads

Published

2021-06-30

How to Cite

Ambroziak, Andrzej. “Load Capacity of Steel-Aluminium Brackets under Static and Cyclic Laboratory Tests”. Archives of Civil Engineering, vol. 67, no. 2, June 2021, pp. 85-99, doi:10.24425/ace.2021.137156.

Issue

Section

Articles

Similar Articles