Proposal for application of risk analysis to assess robustness of floor slabs pre-stressed with unbonded tendoms

Authors

DOI:

https://doi.org/10.24425/ace.2022.140166

Abstract

The list of potential hazards related to concrete elements and structures prestressed with the use of unbonded tendons, including the flat slabs, is long and fairly well recognized. In addition to the standard accidental events this list includes: mishandling during construction, small fire, local corrosion, loss of bond at the anchorage, second order effects, brittle fracture of elements, etc. Despite of these hazards related to unbonded post-tensioning, this type of structures are extensively promoted and used in practice thanks to the possibility of the large span floors and innovative character of this technology. The paper presents a proposal for the application of risk analysis to assess the robustness of structures with flat slabs prestressed with unbonded tendons. The adoption of variables that determine risk and robustness as fuzzy numbers assigned to linguistic variables are proposed. Numerical example is presented to demonstrate risk and robustness assessment of building structure with unbonded post-tensioned slabs supported directly on columns.

References

[1] F. Knoll, T. Vogel, Design for Robustness. Structural Engineering Documents No11. Zurich: IABSE, 2009, ISBN 978-3-85748-120-8.

[2] Santa Fe Institute, RS-2001-009, Working definitions of robustness, 2001. [Online]. Available: http://discuss.santafe.edu/robustness/sories.

[3] E.A.P. Liberati, C.G. Nogueira, E.D. Leonel, “Nonlinear formulation based on FEM, Mazars damage criterion and Fick’s law applied to failure assessment of reinforced concrete structures subjected to chloride ingress and reinforcements corrosion”, Engineering Failure Analysis, 2014, vol. 46, pp. 247-268, DOI: 10.1016/j.engfailanal.2014.09.006.

[4] N.C. Lind, “Measures of vulnerability and damage tolerance”, Reliability Engineering & System Safety, 1995, vol. 48, no. 1, pp. 1-6.

[5] D.M. Frangopol, J.P. Curly, “Effects of damage and redundancy on structural realibility”, Journal of Structural Engineering, 1987, vol. 113, no. 7, pp. 1533-1549.

[6] S. Woo, D.L. O’Neal, “Reliability design and case study of mechanical system like a hinge kit system in refrigerator subjected to repetitive stresses”, Engineering Failure Analysis, 2019, vol. 99, pp. 319-329, DOI: 10.1016/j.engfailanal.2019.02.015.

[7] I.W. Baker, M. Schubert, M.H. Faber, “On assessment of robustness”, Journal of Structural Safety, 2008, vol. 30, pp. 253-267.

[8] ISO Standard 19902, Petroleum and natural gas industries - Fixed steel offshore structures, 2008.

[9] T. Vrouwenvelder, et al., Eds. Risk assessment and risk communication in civil engineering. CIB Report, 259. Rotterdam: CIB General Secretariat, 2001.

[10] EN 1991-1-7, Eurocode 1 - Actions on structures - Part 1-7: General actions - Accidental actions.

[11] A. del Caño, M. Pilar de la Cruz, D. Gómez, M. Pérez, “Fuzzy method for analysing uncertainty in the sustainable design of concrete structures”, Journal of Civil Engineering and Management, 2016, vol. 22, no. 7, pp. 924-935, DOI: 10.3846/13923730.2014.928361.

[12] S. Boral, I. Howard, S.K. Chaturvedi, K. Mc Kee, V.N.A. Naikan, “An integrated approach for fuzzy failure modes and effects analysis using fuzzy AHP and fuzzy MAIRCA”, Engineering Failure Analysis, 2020, vol. 108, ID Article: 104195, DOI: 10.1016/j.engfailanal.2019.104195.

[13] Sz.Woliński, “Defining of the structural robustness”, Bulletin of the Polish Academy of Sciences, Technical Sciences, 2013, vol. 61, no. 1, pp. 137-144, DOI: 10.2478/bpasts-2013-0012.

[14] H. Bandamer, S. Gottwald, Fuzzy Sets, Fuzzy Logic, Fuzzy Methods with Applications. Chichester: J. Wiley&Sons, 1995.

[15] EN 1990:2004 Eurocode- Basis of structural design.

[16] G. Harding, J. Carpenter, “Disproportional collapse of Class 3 buildings: the use of risk assessment”, The Structural Engineering, 2009, vol. 87, no. 15-16, pp. 29-34.

[17] Bai Yu, Hou Jian, Huang Yuan, “Progressive collapse analysis and structural robustness of steel-framed modular buildings”, Engineering Failure Analysis, 2019, vol. 104, pp. 643-656, DOI: 10.1016/j.engfailanal. 2019.06.044.

[18] G. Milani, M. Valente, “Comparative pushover and limit analyses on seven masonry churches damaged by the 2012 Emilia-Romagna (Italy) seismic events: Possibilities of non-linear finite elements compared with pre-assigned failure mechanisms”, Engineering Failure Analysis, 2015, vol. 47, Part A, pp. 129-161, DOI: 10.1016/j.engfailanal.2014.09.016.

[19] Sz. Woliński, T. Pytlowany, “Analysis of the state of prestressed structure using data collection simulation technique”, MATEC Web of Conferences, 2019, vol. 262, DOI: 10.1051/matecconf/201926208006.

[20] Sz. Woliński, T. Pytlowany, “Risk and robustness assessment for floor slabs prestressed with unbonded tendons”, in Konstrukcje betonowe i stalowe, (in Polish). Bydgoszcz: University of Science & Technology, 2015, pp. 137-144.

[21] Sz. Woliński, “Robustness and vulnerability of slab structures”, Procedia Engineering, 2017, vol. 193, pp. 88-95, DOI: 10.1016/j.proeng.2017.06.190.

[22] JCSS: Probabilistic Model Code, The Joint Committee on Structural Safety. [Online]. Available: https://www.jcss-lc.org/jcss-probabilistic-model-code/.

[23] E.A.P. Liberati, C.G. Nogueira, E.D. Leonel, “Nonlinear formulation based on FEM, Mazars damage criterion and Fick’s law applied to failure assessment of reinforced concrete structures subjected to chloride ingress and reinforcements corrosion”, Engineering Failure Analysis, 2014, vol. 46, pp. 247-268, DOI: 10.1016/j.engfailanal.2014.09.006.

[24] B. Rodowitz, M. Schubert, M. Faber Havbro, “Robustness of Externally and Internaly Post Tensioned Bridges”, Beton und Stahlbetonbau, 2008, vol. 103, pp. 16-22, DOI: 10.1002/best.200810111.

[25] B. Rodowitz, Robustheit von Balkenbrucker mit externer und interner Vorspannung. Institut fur Massivbau und Baustofftechnologie, Abtailung Massivebau. Karlsruhe: Universitat Karlsruhe, 2007 (in German).

[26] A. Setareh, H. Saffari, J. Mashhadi, “Assessment of dynamic increase factor for progressive collapse analysis of RC structures”, Engineering Failure Analysis, 2018, vol. 84, pp. 300-310, DOI: 10.1016/j.engfailanal.2017.11.011.

[27] I. Skrzypczak, L. Buda-Ozóg, T. Pytlowany, “Fuzzy method of conformity control for compressive strength of concrete on the basis of computational numerical analysis”, Meccanica, 2016, vol. 51, no. 2, pp. 383-389, DOI: 10.1007/s11012-015-0291-0.

[28] Sz. Woliński, T. Pytlowany, “Parametric Analysis of the Sensitivity of a Prestressed Concrete Beam Using the DOE Simulation Technique”, Archives of Civil Engineering, 2019, vol. 65, no. 4, pp. 97-112, DOI: 10.2478/ace-2019-0049.

Downloads

Published

2022-03-30

How to Cite

Woliński, Szczepan, and Tomasz Pytlowany. “Proposal for Application of Risk Analysis to Assess Robustness of Floor Slabs Pre-Stressed With Unbonded Tendoms”. Archives of Civil Engineering, vol. 68, no. 1, Mar. 2022, pp. 241-53, doi:10.24425/ace.2022.140166.

Issue

Section

Articles

Similar Articles

<< < 3 4 5 6 7 8 9 10 11 12 > >> 

You may also start an advanced similarity search for this article.