Laboratory tests and numerical analysis of façade sub-structure made of austenitic steel

Authors

DOI:

https://doi.org/10.24425/ace.2022.143036

Abstract

This article presents a study of a wall cladding system composed of stainless steel sub-frame and composite, fibre-reinforced concrete cladding panels, which was been installed on a high-rise public building. The study focused on the assessment of strength, safety and durability of design through laboratory tests and numerical analyses. The laboratory tests were conducted using a threedimensional tests stand and a full-scale mock-up of the wall cladding system built at the laboratory using the actually used materials and cladding panels. The boundary conditions and the test loads corresponded to the values of actions determined during the engineering phase of the high-rise building under analysis. Noteworthy, wind actions were verified by supplementary wind tunnel testing. In addition, the stainless steel was also tested to determine the strength properties of the material actually used in construction. These test were carried out just before commencement of the curtain wall installation. The 3D model was constructed with the application of the finite element method (FEM) to obtain adequate representation of geometry, material performance and structural behaviour of the analysed wall cladding system. Particular attention was paid to determination of the parameters defining the behaviour of the cladding system sub-frame from the angle of plastic deformations of the stainless steel and the resulting failure mechanisms of the members of the structure itself. To this end, the stainless steel was subjected to appropriate performance tests to determine material properties including the values of the proportionality limit and yield strength.

References

[1] C. Bedon, D. Honfi, K.V. Machalická, et al., “Structural characterisation of adaptive facades in Europe - part I: Insight on classification rules, Performance Metrics and design methods”, Journal of Building Engineering, 2019, vol. 25; DOI: 10.1016/j.jobe.2019.02.013.

[2] C. Bedon, D. Honfi, K.V. Machalická, et al., “Structural characterisation of adaptive facades in Europe - part II: Validity of conventional experimental testing methods and key issues”, Journal of Building Engineering, 2019, vol. 25; DOI: 10.1016/j.jobe.2019.100797.

[3] C. Bedon, X. Zhang, F. Santos, et al., “Performance of structural glass facades under extreme loads - design methods, existing research, current issues and Trends”, Construction and Building Materials, 2018, vol. 163, pp. 921-937; DOI: 10.1016/j.conbuildmat.2017.12.153.

[4] EN 13830:2015 Curtain walling - Product standard.

[5] M. Cwyl, R. Michalczyk, N. Grzegorzewska, A. Garbacz, “Predicting performance of aluminum - glass composite facade systems based on mechanical properties of the connection”, Periodica Polytechnica Civil Engineering, 2018, vol. 62, no. 1, pp. 259-266; DOI: 10.3311/PPci.9988.

[6] T.G. Theodosiou, A.G. Tsikaloudaki, K.J. Kontoleon, D.K. Bikas, “Thermal bridging analysis on cladding systems for building facades”, Energy and Buildings, 2015, vol. 109, pp. 377-384; DOI: 10.1016/j.enbuild.2015.10.037.

[7] AGS, “Elewacje wentylowane, systemy mocowań elewacji, zawiesia sufitowe, nierdzewne konsole do klinkieru, okien, łączniki, systemy mocowań bipv”. [Online]. Available: https://ags.org.pl/pl/produkty/. [Accessed: 16. Sept. 2021].

[8] EN 1993-1-4:2006 Eurocode 3 - Design of steel structures - Part 1-4: General rules - Supplementary rules for stainless steels.

[9] Design manual for structural stainless steel, 4th. The Steel Construction Institute, 2017.

[10] M. Cwyl, I. Dmowska-Michalak, A. Kaczmarczyk, R. Michalczyk, “Laboratory tests and numerical analysis of aluminum helping hand brackets with polyamide thermal break”, Archives of Civil Engineering, 2022, vol. 68, no. 2, pp. 409-426; DOI: 10.24425/ace.2022.140650.

[11] EN 1991-1-4 Eurocode 1: Actions on structures - Part 1-4: General actions - Wind actions. CEN.

[12] Simulia, ABAQUS v. 6.14; Computer Software and Online Documentation. Providence, RI, USA: Dassault Systems, 2018.

[13] A. Ambroziak, “Load capacity of steel-aluminium brackets under static and cyclic laboratory tests”, Archives of Civil Engineering, 2021, vol. 67, no. 2, pp. 85-99; DOI: 10.24425/ace.2021.137156.

[14] G. Schwind, E. Gerasimova, A. Gavamichev, J. Schneider, “Deflection of a cladding panel of fully tempered glass in curtain wall system”, Magazine of Civil Engineering, 2021, vol. 104, no. 4, pp. 1-15; DOI: 10.34910/MCE.104.3.