Comparative analysis of guyed lattice mast computations in terms of American and European standard

Authors

DOI:

https://doi.org/10.24425/ace.2024.148912

Abstract

The paper presents an analysis of a 100-meter wind measurement guyed mast located in the north-western part of the United States, in the state of Oregon. Using the RFEM software, the influence of the wind on the mast was analyzed according to the guidelines of two standards:. The purpose of this work is to show the differences between the results of static computations of the mast in terms of the considered standards. Due to the limited content of the work, the icing load on the structure was ignored in the analysis and the focus was on determining the response of the mast only in terms of wind action. The author tried to describe the differences in this respect between the standard guidelines American TIA-22-H and European EN 1993-3-1. The comments and conclusions regarding the analysis of guyed masts presented in the article have some practical aspects and can be used in design practice.

References

[1] Dlubal Sofware Sp. z o.o., “Dlubal”. [Online]. Available: https://www.dlubal.com/pl. [Accessed: 12. Apr. 2023].

[2] TIA-222-H: 2018 Structural Standard for Antenna Supporting Structures and Antennas and Small Wind Turbine Support Structures. TIA, 2018.

[3] EN 1993-3-1 Eurocode 3: Design of steel structures. Part 3–1 : Towers, masts and chimneys – Towers and masts. CEN, 2006.

[4] M. Duraczyński, “Research and analysis of wind energy for the energy sector in South – East Poland”, PhD thesis, AGH University of Science and Technology in Krakow, Poland, 2013 (in Polish).

[5] A. Latko, J. Matthai, and A. Latko, "Analysis of wind conditions for the needs of wind energy”, in Wind power – planning and realization. Gdansk, 2002, pp. 1-6 (in Polish).

[6] TIA-222-G:2005 Structural Standard for Antenna Supporting Structures and Antennas. TIA, 2005.

[7] A.M. Rasool, Y.E. Ibrahim, M.U. Qureshi, and Z. Mahmood, “Analysis of communication tower different heights subjected to wind loads using TIA-222-G and TIA-222-H standards”, Journal of Asian Architecture and Building Engineering, vol. 22, no. 4, pp. 2175-2188, 2023, doi: 10.1080/13467581.2022.2145203.

[8] A.M. Rasool, M.U. Qureshi, and M. Ahmad, “A comparative study of the calculation of wind load and analysis of communication tower as per TIA-222-G and TIA-222-H standards”, KSCE Journal of Civil Engineering, vol. 25, no. 2, pp. 646-653, 2021, doi: 10.1007/s12205-020-0662-5.

[9] “ASCE 7 Hazard Tool”. [Online]. Available: https://asce7hazardtool.online/. [Accessed: 10. Apr. 2023].

[10] ASCE/SEI 7-22: Minimum Design Loads and Associated Criteria for Buildings and Other Structures. ASCE, 2022.

[11] “Google Earth”. [Online]. Available: https://earth.google.com/web/. [Accessed: 25. Mar. 2023].

[12] Sz. Pałkowski, Steel structures. Selected issues of calculation and design. Warszawa: PWN, 2009 (in Polish).

[13] Ö. Yapar, “Analysis of earthquake loading, wind loading and ice loading effects on guyed masts”, M.S. – Master of Science, Middle East Technical University, Turkey, 2010.

[14] EN 1991-1-4: 2005 Eurocode 1: Actions on structures. Part 1–4: General actions – Wind actions. CEN, 2005.

[15] PN-EN 1990: 2004 Eurocode: Basis of structural design. PKN, 2004.

[16] R. Pigoń, “Selected problems of the masts analysis taking into account the elasto-plastic guys properties”, PhD thesis, Koszalin University of Technology, Poland, 2022 (in Polish).

[17] EN 1993-1-1 Eurocode 3: Design of steel structures. Part 1–1: General rules and rules for buildings. CEN, 2005.

[18] M. Matuszkiewicz, “Imperfections in calculations of guyed lattice masts”, Archives of Civil Engineering, vol. 60, no. 4, pp. 409-420, 2014, doi: 10.2478/ace-2014-0028.

[19] SOFiSTiK 2016 FEA. Oberschleissheim, Germany, 2016.

[20] M. Matuszkiewicz and R. Pigoń, „Parametric analysis of mast guys within the elastic and inelastic range”, Archives of Civil Engineering, vol. 68, no. 1, pp. 169-187, 2022, doi: 10.24425/ace.2022.140162.

[21] J. Bęc, “Aerodynamics of guyed masts”, Budownictwo i Architektura, vol. 1, no. 1, pp. 103-118, 2007.

[22] J. Bęc and A. Flaga, “Guyed masts subjected to wind and the environmental actions”, in The Fourth European & African Conference on Wind Engineering, EACWE4, 11-15 July 2005, Prague, Czech Republic. Prague: Institute of Theoretical and Applied Mechanics, Academy of Sciences of the Czech Republic, 2005, pp. 32-33.

Downloads

Published

2024-03-30

How to Cite

Pigoń, Renata. “Comparative Analysis of Guyed Lattice Mast Computations in Terms of American and European Standard”. Archives of Civil Engineering, vol. 70, no. 1, Mar. 2024, pp. 289-04, doi:10.24425/ace.2024.148912.

Issue

Section

Articles