Experimental tests of tension connections of steel angle sections of lattice transmission towers

Authors

DOI:

https://doi.org/10.24425/ace.2025.153333

Abstract

In the present paper, the results of experimental tests of bolted connections of angle specimens subjected to tension and connected by one leg are presented. Structural members of such type are commonly applied to the steel lattice supports of overhead electrical lines. The bolted connections of angles connected by one leg to gusset plates are in tension and additional bending moment that results from the eccentricity of the bolt group. The majority of available existing experimental and numerical investigations regarding the bolted connections of steel angles in tension have been conducted using mostly short specimens. Within this paper, the influence of the specimen length on the behaviour of angles connected by one leg in tension is shown on the basis of the comparison of the results from the experimental tests of shorter and longer specimens of the same size of angle section. Equal-leg angles in two cross-section dimensional groups – L90 x 6 and L120 x 8, and of two lengths: 600 mm and 1500 mm were tested. A basic test included determining the destructive force, elongation of a specimen and its deflections. In the case of some specimens, the tests were extended to include strain measurements in characteristic places of the angles - in the middle of the length and in the bolted connection zone. The conclusions from the conducted experimental tests confirm that the length of a specimen has an impact on the results, with a greater effect observed in angles with larger cross-sections, and thus with a greater load eccentricity.

References

[1] E. Bernatowska and L. Ślęczka, “Stress and strain concentrations in steel angle tension members connected by one leg”, Journal of Civil Engineering, Environment and Architecture, vol. 65, pp. 5-16, 2018, doi: 10.7862/rb.2018.19.

[2] E. Bernatowska and L. Ślęczka, “Net section fracture assessment of steel bolted joints with shear lab effect”, MATEC Web of Conferences, vol. 262, art. no. 09002, pp. 1-8, 2019, doi: 10.1051/matecconf/201926209002.

[3] E. Bernatowska and L. Ślęczka, “Numerical study of block tearing failure in steel angles connected by one leg”, Archives of Civil Engineering, vol. 67, no. 1, pp. 269-283, 2021, doi: 10.24425/ace.2021.136473.

[4] E. Bernatowska and L. Ślęczka, “Experimental and numerical investigation into failure modes of tension angle members connected by one leg”, Materials, vol. 14, no. 18, 2021, doi: 10.3390/ma14185141.

[5] E. Bernatowska and L. Ślęczka, “Net section resistance of steel angles connected by one leg”, Archives of Civil Engineering, vol. 68, no. 4, pp. 275-291, 2022, doi: 10.24425/ace.2022.143038.

[6] M. Gupta and M.L. Gupta, “Evaluation of stress distribution in bolted steel angles under tension”, Electronic Journal of Structural Engineering, vol. 4, pp. 17-27, 2004, doi: 10.56748/ejse.438.

[7] D. Agrawal and M.K. Gupta, “Analysis of hot-rolled steel angles under tension”, International Research Journal of Engineering and Technology, vol. 5, pp. 1071-1074, 2018.

[8] C.V. Geethu, G. Unni Kartha, and S. Usha, “Effect of connection eccentricity in the behaviour of steel tension members”, International Journal of Civil Engineering and Technology, vol. 5, pp. 56-65, 2014.

[9] V.F. de Paula, L.M. Bezzera, and W.T. Matias, “Efficiency reduction due to shear lag on bolted cold-formed steel angles”, Journal of Constructional Steel Research, vol. 64, no. 5, pp. 571-583, 2008, doi: 10.1016/j.jcsr.2007.10.008.

[10] Ke Ke, Y.H. Xiong, M.C.H. Yam, A.C.C. Lam, and K.F. Chung, “Shear lag effect on ultimate tensile capacity of high strength steel angles”, Journal of Constructional Steel Research, vol. 145, pp. 300-314, 2018, doi: 10.1016/j.jcsr.2018.02.015.

[11] H.T. Zhu, M.C.H. Yam, A.C.C. Lam, and V.P. Iu, “The shear lag effects on welded steel single angle tension members”, Journal of Constructional Steel Research, vol. 65, pp. 1171-1186, 2009, doi: 10.1016/j.jcsr.2008.10.004.

[12] C. Fang, A.C.C. Lam, and M.C.H. Yam, “Influence of shear lag on ultimate tensile capacity of angles and tees”, Journal of Constructional Steel Research, vol. 84, pp. 49-61, 2013, doi: 10.1016/j.jcsr.2013.02.006.

[13] S. Labocha, W. Barcewicz, S. Wierzbicki, and M. Giżejowski “Wyzwania badawcze związane z realizacją stalowych podpór linii elektroenergetycznych”, Inżynieria i Budownictwo, no. 4, pp. 155-163, 2021.

[14] W. Barcewicz, S. Wierzbicki, M.A. Giżejowski, S. Labocha, and R. Czyż, “Experimental investigation of angle length effect – angles in tension connected by one leg”, in Modern trends in research on steel aluminium and composite structures, M. Giżejowski, et al., Eds. Routledge, 2021, pp. 85-91, doi: 10.1201/9781003132134-7.

[15] EN 1993-1-8 Eurocode 3: Design of steel structures – Part 1-8: Design of joints. Brussels: CEN, 2005.

[16] EN ISO 6892-1:2016 Metallic materials: Tensile testing – Part 1: Method of test at room temperature. Brussels: CEN, 2016.

Downloads

Published

2025-03-30

How to Cite

Barcewicz, Wioleta, et al. “Experimental Tests of Tension Connections of Steel Angle Sections of Lattice Transmission Towers”. Archives of Civil Engineering, vol. 71, no. 1, Mar. 2025, pp. 259-74, doi:10.24425/ace.2025.153333.

Issue

Section

Articles

Similar Articles

<< < 6 7 8 9 10 11 12 13 14 15 > >> 