Hard magnetic material measurements in a pulsed field magnetometer considering coating and eddy current effects

Authors

DOI:

https://doi.org/10.24425/aee.2023.145416

Abstract

Rare-earth permanent magnets are coated in order to avoid corrosion. When considering the rated geometrical properties of a sample, the coating thickness has to be known precisely as it wrongly enlarges the magnetically active volume which in turn affects the accuracy of the measured magnetic properties. In this work, the sensitivity of hard magnetic material property measurements regarding the consideration of different coating thicknesses is evaluated. Moreover, the impact of eddy current effects on the magnetic properties is studied when measuring in an open circuit. Additionally, an outlook for a measurement-based determination of the electric conductivity of permanent magnet samples is given.

References

[1] Orefice M., Eldosouky A., Škulj I., Binnemans K., Removal of metallic coatings from rare-earth permanent magnets by solutions of bromine in organic solvents, RSC Advances, vol. 9, no. 26, pp. 14910–14915 (2019), DOI: 10.1039/C9RA01696A.

[2] Chen Z., Ng A., Yi J., Chen X., Multi-layered electroless Ni–P coatings on powder-sintered Nd–Fe–B permanent magnet, Journal of Magnetism and Magnetic Materials, vol. 302, no. 1, pp. 216–222 (2006), DOI: 10.1016/j.jmmm.2005.09.008.

[3] Gao Y., Bai Y., Zhu H., Liang W., Liu Q., Dong H., Jia R., Ma W., Corrosion Resistance, Mechanical and Magnetic Properties of Cold-Sprayed Al Coating on Sintered NdFeB Magnet, Journal of Thermal Spray Technology, vol. 30, no. 8, pp. 2117–2127 (2021), DOI: 10.1007/s11666-021-01266-z.

[4] Campbell P., Permanent magnet materials and their application, Cambridge University Press (1996).

[5] Cheng C. W., Man H. C., Cheng F. T., Magnetic and corrosion characteristics of Nd-Fe-B magnet with various surface coatings, IEEE Transactions on Magnetics, vol. 33, no. 5, pp. 3910–3912 (1997), DOI: 10.1109/20.619612.

[6] Fliegans J., Delette G., Dobrynin A. N., Dempsey N. M., Givord D., Closed-Circuit Versus Open-Circuit Characterization of Hard Magnets, IEEE Transactions on Magnetics, vol. 55, no. 2, pp. 1–5 (2019), DOI: 10.1109/TMAG.2018.2883917.

[7] Dinca C., Motor design for maximum material exploitation and magnetization procedure with in-line quality check for mass production, PhD Thesis, Faculty of Electrical Engineering, TU Berlin, Berlin (2017).

[8] Fiorillo F., Beatrice C., Bottauscio O., Patroi E., Measuring the Hysteresis Loop of Permanent Magnets with the Pulsed Field Magnetometer, IEEE Transactions on Magnetics, vol. 43, no. 7, pp. 3159–3164 (2007), DOI: 10.1109/TMAG.2007.893536.

[9] Tellinen J., A simple scalar model for magnetic hysteresis, IEEE Transactions on Magnetics, vol. 34, no. 4, pp. 2200–2206 (1998), DOI: 10.1109/20.703856.

[10] Polinder H., Hoeijmakers M. J., Eddy-current losses in segmented surface-mounted magnets of a PM machine, IEE Proceddings-Electric Power Applications, vol. 146, no. 3, pp. 261–266 (1999), DOI: 10.1049/ip-epa:19990091.

[11] Jiles D. C., Modelling the effects of eddy current losses on frequency dependent hysteresis in electrically conducting media, IEEE Transactions on Magnetics, vol. 30, no. 6, pp. 4326–4328 (1994), DOI: 10.1109/20.334076.

[12] Steentjes S., Boehmer S., Hameyer K., Permanent Magnet Eddy Current Losses in 2-D FEM Simulations of Electrical Machines, IEEE Transactions on Magnetics, vol. 51, no. 3, pp. 1–4 (2015), DOI: 10.1109/TMAG.2014.2362551.

Downloads

Published

2023-06-30

How to Cite

Kern, Alexander, et al. “Hard Magnetic Material Measurements in a Pulsed Field Magnetometer Considering Coating and Eddy Current Effects”. Archives of Electrical Engineering , vol. 72, no. 2, June 2023, pp. 407-14, doi:10.24425/aee.2023.145416.

Issue

Section

Articles

Most read articles by the same author(s)

Similar Articles

<< < 5 6 7 8 9 10 11 12 13 14 > >> 

You may also start an advanced similarity search for this article.