Controlled pre-magnetization method for inrush current reduction in electric arc furnace transformers

Authors

  • Sławomir Sowa Institute of Electrical Engineering and Electronics Poznan University of Technology, Polan https://orcid.org/0000-0001-9030-7185
  • Vasyl Hudym Lviv State University of Life Safety, Faculty of Fire and Technogenic Safety Ukraine
  • Sławomir Ziarkowski Cracow University of Technology, Faculty of Electrical and Computer Engineering Poland
  • Vira Kosovska Lviv Polytechnic National University, Faculty of Management and Business Ukraine
  • Solomia Kosovska Ivan Franko National University of Lviv, Faculty of Economics Ukraine

DOI:

https://doi.org/10.24425/aee.2026.6352

Abstract

This paper investigates transformer inrush currents during the energisation of arc furnace transformers in electric arc furnace (EAF) power supply systems. The study focuses on an industrial DSP-100 installation operating with harmonic filters and reactive-power compensation equipment. A nonlinear reduced-order lumped-parameter model is formulated using explicit phase-domain relations for the supplying-system equivalent, the furnace-transformer branch, the connected filter/compensation branches, and the nonlinear magnetic circuit. The surviving DSP-100 oscillograms are used as an experimental anchor and for a waveform-level consistency assessment of peak current, inter-phase peak-current variation, and transient decay. Because the original high-resolution recorder export, complete channel documentation, and recorder characteristics are no longer available, this comparison is not presented as a unique experimental validation of the nonlinear saturation law or of the detailed nonsinusoidal inrush waveform. A model-level evaluation framework for controlled pre-magnetization is then formulated using peak inrush current, transient decay time, and an energy-based transient severity index. Relative peak-current error and RMSE are retained as waveform-consistency metrics, while the practical interpretation of the severity index is linked to equipment-specific I²t withstand limits. The experimentally anchored model provides a basis for comparative and sensitivity assessment of controlled pre-magnetization in the DSP-100 operating environment. Prototype-level confirmation of controller performance, nonlinear-waveform fidelity, and the influence on associated compensation and filtering equipment remains a subject of further industrial validation.

Downloads

Published

2026-10-12

How to Cite

Sowa, Sławomir, et al. “Controlled Pre-Magnetization Method for Inrush Current Reduction in Electric Arc Furnace Transformers”. Archives of Electrical Engineering , Oct. 2026, pp. 1-25, doi:10.24425/aee.2026.6352.

Issue

Section

Article