Sensitivity Analysis of Acoustic Parameters in a Theatre Hall: A Case Study of the Maria Zankovetska Theatre in Lviv

Authors

  • Jarosław Rubacha Department of Mechanics and Vibroacoustics, Faculty of Mechanical Engineering and Robotics AGH University of Krakow Krakow, Polan
  • Adam Pilch Department of Mechanics and Vibroacoustics, Faculty of Mechanical Engineering and Robotics AGH University of Krakow Krakow, Polan
  • Roman Kinasz Department of Geomechanics, Civil Engineering and Geotechnics Faculty of Civil Engineering and Resource Management, AGH University of Krakow Krakow, Poland
  • Wojciech Binek Department of Mechanics and Vibroacoustics, Faculty of Mechanical Engineering and Robotics AGH University of Krakow Krakow, Polan
  • Tadeusz Kamisiński Department of Mechanics and Vibroacoustics, Faculty of Mechanical Engineering and Robotics AGH University of Krakow Krakow, Polan
  • Mykhaylo Melnyk Department of Computer Aided Design Systems, Lviv Polytechnic National University Lviv, Ukraine

DOI:

https://doi.org/10.24425/aoa.2025.154826

Abstract

This article explores the potential for modifying acoustic parameters within a theatre hall, using the Maria Zankovetska Theatre in Lviv, as a case study. The study used sensitivity analysis to evaluate how changes in the sound absorption of specific surfaces affect selected acoustic parameters in the horseshoe-shaped theatre hall. A numerical model of the hall is developed and calibrated based on in-situ acoustic measurements to assess the sensitivity of parameters such as reverberation time (T20), early decay time (EDT), clarity (C50), and early sound strength (G80). The analysis reveals that surfaces such as the stage tower ceiling, stage walls with curtains, audience walls, and seating have the most significant impact on the acoustic parameters. Modifying the sound absorption of these surfaces can affect T20, EDT, C50, and G80. Notably, increasing the absorption of a single surface might not significantly alter C50 and G80 values, whereas reducing the absorption of surfaces such as seating can lead to noticeable changes in these parameters. These findings provide valuable insights for future renovations and acoustic adjustments, aiming to optimize the theatre’s acoustic performance while preserving its historical character.

Published

2025-09-24

How to Cite

Rubacha, Jarosław, et al. “Sensitivity Analysis of Acoustic Parameters in a Theatre Hall: A Case Study of the Maria Zankovetska Theatre in Lviv”. Archives of Metallurgy and Materials, vol. 71, no. 4, Sept. 2025, pp. 307-20, doi:10.24425/aoa.2025.154826.

Issue

Section

Articles