Comparison of selected methods for measuring the luminous flux of solid-state light sources

Authors

  • Krzysztof Górecki Department of Marine Electronics, Gdynia Maritime University, ul. Morska 81-87, 81-225 Gdynia, Poland https://orcid.org/0000-0002-9857-8235
  • Aleksandra Kalinowska Faculty of Electrical Engineering, Gdynia Maritime University, ul. Morska 81-87, 81-225 Gdynia, Poland
  • Przemysław Ptak Department of Marine Electronics, Gdynia Maritime University, ul. Morska 81-87, 81-225 Gdynia, Poland https://orcid.org/0000-0002-4701-2995

DOI:

https://doi.org/10.24425/opelre.2024.149234

Abstract

The paper presents a simple method of measuring the luminous flux value dedicated to LED light sources. This method uses information about a spatial radiation pattern of the lighting source under test and the results of illuminance measurements at the axis of this source. The method is described and the results of the measurements obtained using this method and the classical method are compared and discussed. Tests have been carried out for LED modules of different geometries. The measurement error of the considered method is analysed.

Downloads

Published

2026-03-07

How to Cite

Górecki, Krzysztof, et al. “Comparison of Selected Methods for Measuring the Luminous Flux of Solid-State Light Sources”. Opto-Electronics Review, vol. 32, no. 1, Mar. 2026, p. e149234 , doi:10.24425/opelre.2024.149234.

Issue

Section

Articles

Similar Articles

1 2 3 4 5 6 7 8 9 10 > >> 