Vacuum anodic bonding is widely applied for hermetic packaging of microelectro­mechanical (MEMS) devices; however, obtaining reliable high-quality bonds under vacuum conditions remains challenging. We have assumed that main reason for that is reduced heat transfer between bonded structures and a heating stage. To prove that we have investigated thermal phenomena occurring during vacuum anodic bonding using infrared thermography, temperature of silicon and silicon-glass structures was continuously monitored during heating, evacuation, and pressurisation of a custom-built vacuum bonding system. The measurements revealed that, after reaching high vacuum, the temperature of bonded elements decreased by approximately 40–60%, despite only minor changes in the hot plate temperature. The effect was observed for both single-layer and multilayer structures and was attributed to the disappearance of gas-assisted heat transfer under vacuum conditions. The obtained results explain the low ion currents and reduced bonding efficiency frequently observed during vacuum anodic bonding. Based on experimental observations, several practical approaches for improving heat transfer were proposed. Their implementation increased the bonding yield from approximately 25% to 75%. The presented methodology provides a useful diagnostic tool for optimising vacuum anodic bonding processes and improving the reliability of MEMS packaging.Vacuum anodic bonding is widely applied for hermetic packaging of microelectro­mechanical (MEMS) devices; however, obtaining reliable high-quality bonds under vacuum conditions remains challenging. We have assumed that main reason for that is reduced heat transfer between bonded structures and a heating stage. To prove that we have investigated thermal phenomena occurring during vacuum anodic bonding using infrared thermography, temperature of silicon and silicon-glass structures was continuously monitored during heating, evacuation, and pressurisation of a custom-built vacuum bonding system. The measurements revealed that, after reaching high vacuum, the temperature of bonded elements decreased by approximately 40–60%, despite only minor changes in the hot plate temperature. The effect was observed for both single-layer and multilayer structures and was attributed to the disappearance of gas-assisted heat transfer under vacuum conditions. The obtained results explain the low ion currents and reduced bonding efficiency frequently observed during vacuum anodic bonding. Based on experimental observations, several practical approaches for improving heat transfer were proposed. Their implementation increased the bonding yield from approximately 25% to 75%. The presented methodology provides a useful diagnostic tool for optimising vacuum anodic bonding processes and improving the reliability of MEMS packaging.

Downloads

Published

2026-10-21

How to Cite

Grzebyk, Tomasz, et al. “Identifying Heat Transfer Problems During Vacuum Anodic Bonding by Thermal Imaging Measurements”. Opto-Electronics Review, vol. 34, no. 4, Oct. 2026, p. 7471, doi:10.24425/opelre.2026.7471.

Issue

Section

Articles

Similar Articles

1 2 3 4 5 6 7 8 9 10 > >> 

You may also start an advanced similarity search for this article.