Behavior of damaged TBM tunnel under MJS and Micro-disturbance grouting treatment: a case study

Autor

DOI:

https://doi.org/10.24425/ace.2023.145271

Abstrakt

The operating subway tunnel is often damaged due to excessive deformation in China. In order to ensure the safe for operation, remediation and protection measures must be taken, especially in soft soil areas. This paper presents a case study on remedial scheme of damaged TBM (Tunnel Boring Machine) tunnel adjacent to excavation combining with MJS (Metro Jet System) and micro-disturbance grouting technology in Hangzhou, China. The track bed settlement, horizontal displacement and convergence of the TBM tunnel caused by MJS and micro-disturbance grouting construction were analyzed and discussed. The results showed the characteristics of soil layer under the tunnel have significant influence on the treatment effect. Even if multiple grouting was adopted, the treatment failure may occur under the combination action of external loads such as traffic load or surcharge load, which should be considered when civil engineers design remediation scheme. The results can provide practical experience and guidance for similar treatment scheme of damaged TBM tunnel.

Bibliografia

[1] Y. Tan, X. Li, Z. Kang, J. Liu and Y. Zhu, “Zoned excavation of an oversized pit close to an existing metro line in stiff clay: Case study”, Journal of Performance of Constructed Facilities, vol. 29, no. 6, art. no. 04014158, 2015, doi: 10.1061/(ASCE)CF.1943-5509.0000652.

[2] M.G. Li, J.H. Wang, J.J. Chen, and Z.J. Zhang, “Responses of a newly built metro line connected to deep excavations in soft clay”, Journal of Performance of Constructed Facilities, vol. 31, no. 6, art. no. 04017096, 2017, doi: 10.1061/(ASCE)CF.1943-5509.0001091.

[3] P. Szklennik, “Numerical determination of load of a model tunnel lining, taking into account different heights of soil backfill”, Archives of Civil Engineering, vol. 68, no. 3, pp. 289-305, 2022, doi: 10.24425/ace.2022.141886.

[4] A.M. Sklodowska and M. Mitew-Czajewska, “The influence of electronic detonators on the quality of the tunnel excavation”, Archives of Civil Engineering, vol. 67, no. 3, pp. 333-349, 2021, doi: 10.24425/ace.2021.138059.

[5] M. Zhu, X. Gong, X. Gao, et al., “Remediation of damaged shield tunnel using grouting technique: serviceability improvements and prevention of potential risks”, Journal of Performance of Constructed Facilities, vol. 33, no. 6, art. no. 04019062, 2019, doi: 10.1061/(ASCE)CF.1943-5509.0001335.

[6] C.T. Chang, C.W. Sun, S.W. Duann, and R.N. Hwang, “Response of a taipei rapid transit system (TRTS) tunnel to adjacent excavation”, Tunnelling and Underground Space Technology, vol. 16, no. 3, pp. 151-158, 2001, doi: 10.1016/S0886-7798(01)00049-9.

[7] X. Huang, H.F. Schweiger, and H. Huang, “Influence of deep excavations on nearby existing tunnels”, International Journal of Geomechanics, vol. 13, no. 2, pp. 170-180, 2013, doi: 10.1061/(ASCE)GM.1943-5622.0000188.

[8] W.C. Cheng, Z.P. Song, W. Tian, and Z.F. Wang, “Shield tunnel uplift and deformation characterization: A case study from Zhengzhou metro”, Tunnelling and Underground Space Technology, vol. 79, pp. 83-95, 2018, doi: 10.1016/j.tust.2018.05.002.

[9] H. Mohamad, K. Soga, P.J. Bennett, R.J. Mair, and C.S. Lim, “Monitoring twin tunnel interaction using distributed optical fiber strain measurements”, Journal of Geotechnical and Geoenvironmental Engineering, vol. 138, no. 8, pp. 957-967, 2012, doi: 10.1061/(ASCE)GT.1943-5606.0000656.

[10] D.M. Zhang, Z.S. Liu, R.L. Wang, and D.M. Zhang, “Influence of grouting on rehabilitation of an over-deformed operating shield tunnel lining in soft clay”, Acta Geotechnica, vol. 14, no. 4, pp. 1227-1247, 2019, doi: 10.1007/S11440-018-0696-8.

[11] H. Huang, H. Shao, D. Zhang, and F. Wang, “Deformational responses of operated shield tunnel to extreme surcharge: A case study”, Structure and Infrastructure Engineering, vol. 13, no. 3, pp. 345-360, 2017, doi: 10.1080/15732479.2016.1170156.

[12] X. Li and D. Yuan, “Development of the safety control framework for shield tunneling in close proximity to the operational subway tunnels: case studies in mainland China”, SpringerPlus, vol. 5, no. 1, art no. 527, 2016, doi: 10.1186/s40064-016-2168-7.

[13] D. Jin, D. Yuan, X. Li, and H. Zheng, “An in-tunnel grouting protection method for excavating twin tunnels beneath an existing tunnel”, Tunnelling and Underground Space Technology, vol. 71, pp. 27-35, 2018, doi: 10.1016/j.tust.2017.08.002.

Opublikowane

2023-06-30

Jak cytować

Feng, Shi, i in. „Behavior of Damaged TBM Tunnel under MJS and Micro-Disturbance Grouting Treatment: A Case Study”. Archives of Civil Engineering, t. 69, nr 2, czerwiec 2023, s. 339-52, doi:10.24425/ace.2023.145271.

Numer

Dział

Articles

Podobne artykuły

1 2 3 4 5 6 7 8 9 10 > >> 

Możesz również Rozpocznij zaawansowane wyszukiwanie podobieństw dla tego artykułu.