Handheld ED-XRF spectrometers in geochemical investigation: Comparative studies for glacial deposits from Spitsbergen

Authors

  • Lidia Kozak Adam Mickiewicz University in Poznań, Faculty of Chemistry, Department of Analytical Chemistry, Uniwersytetu Poznańskiego 8, 61-614 Poznań, Poland https://orcid.org/0000-0003-2862-1258
  • Juliana Silva Souza Adam Mickiewicz University in Poznań, Faculty of Chemistry, Department of Analytical Chemistry, Uniwersytetu Poznańskiego 8, 61-614 Poznań, Poland
  • Adam Nawrot Institute of Geophysics Polish Academy of Sciences, Księcia Janusza 64, 01-452 Warszawa, Poland https://orcid.org/0000-0002-6619-6478
  • Jędrzej Proch Adam Mickiewicz University in Poznań, Faculty of Chemistry, Department of Analytical Chemistry, Uniwersytetu Poznańskiego 8, 61-614 Poznań, Poland https://orcid.org/0000-0003-0023-044X
  • Marcin Kaźmierski Adam Mickiewicz University in Poznań, Faculty of Geographical and Geological Sciences, Bogumiła Krygowskiego 10, 61-680 Poznań, Poland
  • Agnieszka Zawieja MEWO S.A., Starogardzka 16, 83-010 Straszyn, Poland
  • Przemysław Niedzielski Adam Mickiewicz University in Poznań, Faculty of Chemistry, Department of Analytical Chemistry, Uniwersytetu Poznańskiego 8, 61-614 Poznań, Poland https://orcid.org/0000-0002-2787-9057

DOI:

https://doi.org/10.24425/ppr.2021.137141

Abstract

This study presents the determination of the content of selected metals (Ba, Ca, Fe, Nb, Rb, Sr, Y, Zn, and Zr) in postglacial deposits from two glacial valleys (Ebbadalen and Elsadalen) in the Petunia Bay (southern Spitsbergen). The aim of the research was to experimentally check the usefulness of the handheld energy dispersive X-ray fluorescence technique in the study of samples from the polar zone, before performing the future field tests. Deposit analyses were performed (in parallel) with two handheld X-ray fluorescence spectrometers from different manufacturers, to investigate the accuracy and reliability of the instruments. The statistical analysis of the results indicated that the measurements carried out with two spectrometers were statistically significantly different, which was probably due to the different calibration characteristics used by the manufacturers. However, the analysis of the spatial distribution of element concentrations using Geographic Information System tools showed that the distribution maps of elements concentrations were similar regardless of the spectrometer used in the analyses.

Downloads

Published

2021-09-03

How to Cite

Kozak, Lidia, et al. “Handheld ED-XRF Spectrometers in Geochemical Investigation: Comparative Studies for Glacial Deposits from Spitsbergen”. Polish Polar Research, vol. 42, no. 3, Sept. 2021, pp. 163–172, doi:10.24425/ppr.2021.137141.